| producent | IKA |
|---|---|
| nr katalogowy | IRM-20-0008802500 |
| opakowanie | 10x1 szt. |
C 200, Calorimeter C 200-System consists of the following components: Measuring cell C 200 Decomposition vessel C 5010 Oxygen filling station C 248 Consumables for calibrations and installation Space-saving and low cost combustion calorimeter for determing gross calorific values of liquid and solid samples. Validation according to DIN 51900,ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711. Suitable for teaching and training, as well (f.e tecnical- schools, universities) and for industriell laboratories with less analyses.. Manual handling for water and oxygen filling. Four different working methods, isoperibolic, dynamic, manual, time controlled makes possible an ideal adjustment of different operating tasks. Clear and easily explained display which is simply to use . With an external power pack, "world tension useable" from 100 - 240 V AC, 50/60 Hz. The operating voltage of the calorimeter is 24 V DC low- voltage. Friendly in aftersales Manual ( teaching mode): ignition and end of the measurement will be done by the operator himself; the temperature increase will be indicated at the display each minute. All calculations have to be done manually. At the other three modes ignition and calculation of the gross calorific value will be done automatically. The gross calorific value will be shown on the display. Acid corrections and calculations of the net calorific value have to be done manually. The modes have different measuring times: Isoperibolic: approx: 17 min. Dynamic : approx. 8 min Manual : approx. 17 min (depend on the operator) Time controlled : 14 min The decomposition vessel can be equiped in to use an combustible crucibles C 14 (accessory C 5010.4 attachment is neessary) User-friendly software C 6040 Calwin for controlling the calorimeter and administration of measuring data (asseccory). Transfer of the datas to Excel or Word are possible Up to eight IKA measuring cells can be controlled by a single PC, using a multiserial plug in card PCI 8.2 (accessory) more
Zadaj nam pytanie o ten produkt — chętnie pomożemy.
| czas dostawy | na stanie u producenta |
|---|
C 6, Quartz dish, big
IKA
IRM-20-0000355100
C 9, Gelatine capsules
IKA
IRM-20-0000749900
C 10, Acetobutyrate capsules
IKA
IRM-20-0000750000
C 29 (DIN 477), Pressure gauge, oxygen
IKA
IRM-20-0000750200
C 43, Benzoic acid, NIST 39j, 30 g
IKA
IRM-20-0000750600
C 710.2, Set of VA combustion crucibles, big
IKA
IRM-20-0001483500
C 710.4, Cotton thread, cut to length
IKA
IRM-20-0001483700
C 21, Pelleting press
IKA
IRM-20-0001605300
C 4, Quartz dish
IKA
IRM-20-0001695500
C 5, Set of VA combustion crucibles
IKA
IRM-20-0001749500
C 12, Combustion bags, 40 x 35 mm
IKA
IRM-20-0002201400
C 12 A, Combustion bags, 70 x 40 mm
IKA
IRM-20-0002201500
C 5010.4, Attachment for combustible crucible C 14
IKA
IRM-20-0003016900
C 5010.5, Crucible holder, big
IKA
IRM-20-0003055900
C 15, Parafilm strips
IKA
IRM-20-0003131100
C 723, Benzoic acid, blister package
IKA
IRM-20-0003243000
C 200.1, Measuring cup, 2000 ml
IKA
IRM-20-0003548900
C 723 Big Pack, Benzoic acid, blister package
IKA
IRM-20-0003717400
C 16, Parafilm, 1000 x 50 mm
IKA
IRM-20-0003801100
C 17, Paraffin, liquid, 30 ml
IKA
IRM-20-0003801200
C 6040 CalWin, Calorimeter PC software
IKA
IRM-20-0004040500
C 5010.3, Ignition wire, spare
IKA
IRM-20-0007122800
C 5030, Venting station
IKA
IRM-20-0007198000
C 14, Combustible crucibles
IKA
IRM-20-0007224500
C 26, Prep stand
IKA
IRM-20-0008804000
Documents for qualification, for analyzing equipment
IKA
IRM-20-0010006578
Factory Calibration Certificate, for analyzing equipment
IKA
IRM-20-0010006580
IQ/OQ Documentation, for analyzing equipment
IKA
IRM-20-0010006582
General Certificates (2.2 oder 3.1), for analyzing equipment
IKA
IRM-20-0010010808
C 200.RC, Set of hoses
IKA
IRM-20-0020010835
C 6000.1, Water protect, 100 ml
IKA
IRM-20-0020014031
C 5010, Decomposition vessel
IKA
IRM-20-0020128010